Wastewater heat exchanger & Wastewater technology

Our product portfolio for wastewater heat recovery. System solutions for multi-story residential construction & industry.

Plate heat exchanger

ABW-DWT

The ABW-DWT enables heat recovery from wastewater with high volume flows. The range of applications extends from domestic and industrial mixed wastewater systems to swimming pools and agricultural use in aquacultures. The recovered heat can be used indirectly via any heat pump or directly via an intermediate circuit for heating drinking water.

Application*
Industry, swimming pools, apartment blocks, sewage treatment plants, agriculture, etc.

*Use of gray or mixed wastewater, prefilter necessary for domestic mixed wastewater, restriction due to high chloride content
Performance*
up to 154 kW

*Application case wastewater; continuous wastewater flow, temperature reduction by heat pump
Heat exchanger surface*
6.70 – 67.2 m²
2 – 10 plates

*Can be switched in cascade for larger area
Material
Stainless steel (1.4404)
max. Wastewater temperature
70°C
Dimensions
Height: 1500mm
Length: 1800mm
Width: 780mm
Empty weight
up to approx. 500kg
Connections
Heat exchanger: DN20 – 65 (1" – 2.5")
Overflow: DN110
Gray water: DN110
Drain: DN110
Cleaning
Integrated extremely durable and robust surface cleaning system for sustained efficiency
Wastewater heat exchanger ABW-DWT by revincus Wastewater heat exchanger ABW-DWT by revincus Detail shot Wastewater heat exchanger ABW-DWT by revincus Detail shot Wastewater heat exchanger ABW-DWT by revincus with and without cladding
Downloads

Wastewater rake

ABW-SWR

The ABW-SWR is used for the pre-cleaning of wastewater streams. Heavily polluted wastewaters are freed from suspended solids and can be used downstream by the ABW-DWT for heat recovery. The filter material is automatically cleaned and washed away from the filtered wastewater after the heat exchange process.

Application*
Fecal-containing wastewaters, wastewater with coarse solid load
*for filtering out wet wipes, sanitary napkins etc.
Volume flow
min. 1.25 m³/h
max. 70.0m³/h
Drive of the rake
Electric motor
Material
Stainless steel (1.4404)
max. Wastewater temperature
70°C
Dimensions
Height: 2700mm
Length: 1400mm
Width: 780mm
Empty weight
up to approx. 150kg
Connections
Inlet: DN200
filtered water: DN200
Drain: DN300
Wastewater heat exchanger ABW-SWR by revincus Wastewater heat exchanger ABW-SWR by revincus Wastewater heat exchanger ABW-SWR by revincus Detail shot Wastewater heat exchanger ABW-SWR by revincus Black water rake in function

Buffer storage heat exchanger

ABW-PSW

The wastewater heat exchanger has been specially developed for the heat recovery from greywater. It can be used in buildings with at least 20 inhabitants and can be combined with any brine heat pump. In buildings without separate greywater management, the ABW-K2 can be pre-installed.

Application
non-fecal contaminated wastewater
Performance*
5.5kW

*Application case domestic greywater; reduction from 25°C to 8°C by heat pump
Heat exchanger surface
6.6m²
Design
700 L capacity
min. 20 people
max. 40 people

Can be switched in cascade for higher capacity
Dimensions
Height: 1400mm
Diameter: 780mm
Connections
Heat exchanger: DN20(1")
Overflow: DN50
Greywater: DN75
Drain: DN110
Cleaning
Integrated brush cleaning system for sustained efficiency
Wastewater heat exchanger ABW-PSW by revincus Wastewater heat exchanger ABW-PSW by revincus Detail shot Wastewater heat exchanger ABW-PSW by revincus Detail shot Wastewater heat exchanger ABW-PSW by revincus Detail shot
Downloads

Wastewater switch

ABW-K2

The wastewater switch ABW-K2 is used to separate grey and black water on a mixed wastewater pipe. By integrating a wastewater switch, the use of wastewater heat recovery - without retrofitting a separate greywater pipe - is possible in existing buildings.

Application
Separation of grey & black water on the downpipe
Dimensions
Height: 445mm
Width: 320mm
Depth: 330mm
Connections
Wastewater connection: DN110
Greywater connection: DN75
Blackwater connection: DN110
Overflow: DN110
Wastewater switch ABW-K2 by revincus Wastewater switch ABW-K2 by revincus Wastewater switch ABW-K2 by revincus Wastewater switch ABW-K2 by revincus
Downloads

Flush function button

SFT

The flush function button SFT is used to detect toilet flushes (black water). This is installed in combination with the wastewater switch ABW-K2 and ensures error-free separation of black and grey water on the downpipes.

Application area
Multi-family house & residential block
Data transmission method
LoRa radio
Range
up to 2km
Transmission frequency
867.5 & 868.5 MHz
Bandwidth
125 kHz
Channels
18
Transmission power
5-20 dBm
Data packet size
16 byte
Dimensions (without antenna)
Width: 80mm
Height: 105mm
Depth: 40mm
Power supply
DC 10-28V
max. 0.25 A
Flush function button SFT by revincus

Layer Storage Heat Exchanger

ABW-SSW 180

The layer storage heat exchanger ABW-SSW 180 has been specially developed for heat recovery from domestic gray water.

Applications
domestic gray water
Temperature Zones
4 zones
Performance by Zones*
1.5 kW
1.2 kW
1.0 kW
0.7 kW

*Application case domestic gray water; lowering of the zones from 35|30|25|20 °C to 14°C by water with 12°C
Heat exchanger surface
3.3m²
Design
max. 8 people
Dimensions
Height: 1800mm
Diameter: 450mm
Layer storage heat exchanger ABW-SSW from revincus Layer storage heat exchanger ABW-SSW from revincus Layer storage heat exchanger ABW-SSW from revincus Layer storage heat exchanger ABW-SSW from revincus
Downloads

Do you have any questions?

Contact us!

Felix Drechsel

Facilities

revincus facilities Jena

Jena

Löbdergraben 28
07743 Jena

revincus facilities Weimar

Weimar

Schlachthof-Str. 8
99423 Weimar

© revincus GmbH